this post was submitted on 24 Sep 2024
23 points (72.5% liked)
Technology
59436 readers
3020 users here now
This is a most excellent place for technology news and articles.
Our Rules
- Follow the lemmy.world rules.
- Only tech related content.
- Be excellent to each another!
- Mod approved content bots can post up to 10 articles per day.
- Threads asking for personal tech support may be deleted.
- Politics threads may be removed.
- No memes allowed as posts, OK to post as comments.
- Only approved bots from the list below, to ask if your bot can be added please contact us.
- Check for duplicates before posting, duplicates may be removed
Approved Bots
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
48V, 10A at 6 feet or less length requires 16awg wire for <=3% loss (which is the critical appliance standard rather than the more lax <= 10% used for most DC circuits). That's a wire with a conductor diameter of 1.3mm ~= 0.05in.
The cable probably isn't 10A rated. But, it's not an overly thick wire to get it done. Most of the girth is insulation and shielding.
This is overly simplified. And, I didn't care to watch the video.
edit: replaced mistaken > with <