this post was submitted on 29 Jul 2023
103 points (95.6% liked)
homeassistant
12025 readers
113 users here now
Home Assistant is open source home automation that puts local control and privacy first. Powered by a worldwide community of tinkerers and DIY enthusiasts. Perfect to run on a Raspberry Pi or a local server. Available for free at home-assistant.io
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
A lot of smart outlets develop problems over time from the inductive surge current on electric motor startup (air conditioner, fridge, dehumidifier). The current ratings in ads are generally for resistive loads. Inductive load limits can be 30% less.
I have a Sonoff S31 on my fridge for about 3 years now for power monitoing and have had no issues. I'm sure the fact I don't switch it on and off and it's locked to stay on on power up helps prolong it's life. If you never switch the load I don't see how it's life could be impacted. But I do have a temp sensor on the fridge so any failures I would be alerted to.