this post was submitted on 16 Dec 2023
14 points (100.0% liked)
Electricians
481 readers
1 users here now
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
This (fairly simple) diagram shows one way.
http://www.mgb-stuff.org.uk/images/haz3.jpg
You have the hazard switch which, when engaged, connects both L and R to the flasher circuit and disconnects the indicator switch. The turn indicator switch is either off or it connects left or right to the flasher circuit (via the hazard switch).
The page that this is from has some additional ways to do it.
http://www.mgb-stuff.org.uk/s_hazard.htm
If you are still struggling, let us know how the blinkers are wired and share a wiring diagram if possible?
If you ignore the hazard switch in the image I posted that is what I have wired. 1 & 3 on the blinker switch are connected to blinkers on each side. I got lost when the hazard came into play.. Do you understand what the directions are saying with "+ switch negative", "negative led light inside switch", etc? I looked at the diagrams you linked but it's hurting my brain even more at this point :)
Ok sorry for this janky drawing but I think this is a correct representation of how to wire everything. Maybe?
What should happen is with hazards on, both L and R lights blink together and the turn signal switch has no effect. When hazards are off, the appropriate turn signal operates if you select R or L turn otherwise nothing flashes.
Thanks! I think that is what I was originally trying. By adding the hazard "3" connection to both sides of the blinkers it ends up connecting them so that whether I use blinkers or hazards it's all the same. I'm going to do some more debugging with a multimeter and see if I can understand the switch more. I'll probably just end up getting diodes and wiring it like this diagram with diodes. Just bothering me that I might be missing something.
Gotcha. I think diodes are the easiest solution here. Idk what they were thinking with these instructions.
If the hazard switch was a dual pole, then you could connect the right side to one pole and the left side to the other pole and then it would only connect Left and Right when hazards are on.
With diodes:
With dual pole hazard switch:
Added the diodes today and it's all working great! Thanks for helping me understand this!
That's awesome, congrats!